Symptom What's going on What to do

Token Expired on the tablet

Tokens are valid for 30 minutes.

In Business Central, run Register Tablet Client again and use the new token.

The barcode won't scan

Some built-in scanners can't read a barcode on a monitor.

Type the token in.

The wizard won't go past Review Settings

The Portal Fwk. Application ID or BC Web Service URL is empty.

Fill them in. Register the tablet in Business Central

Error AADSTS700016

Your organisation hasn't consented to the Clever application.

An administrator chooses Authorisation on the “MES Setup” screen and signs in.

The tablet can't reach Business Central

Network or a wrong BC Web Service URL.

Check the tablet's connection and the URL.

 

The tablet connects but shows nothing

 
Symptom What to check

No Workspaces to choose

Is the tablet's Terminal assigned any Workspaces? Set up Terminals and their Workspaces

The Terminal isn't in the list

Was it created before the tablet was first opened?

A Workspace you expect is missing

Is Show in MES on for its centre, and has a Workspace been created? Create Workspaces from your Machine Centres and Work Centres

There are no Machine Centers or Work Centers available.

No centre is set up and eligible for this Workspace. Check Show in MES and the routing lines.

There are no Operators available.

No operator is set up for this centre, or they're all blocked. Check “MES Operators” on the “MES Setup” screen.

 

Operators can't find their job

The job list depends on the Workspace's centre and the settings on the “MES Setup” screen. Configure what operators see

  • Is the production order released?

  • Is the operation routed to this Workspace's centre? A Work Centre Workspace only sees operations routed directly to that Work Centre.

  • Does it have quantity to start? If not, turn on Show Ops with no Qty. to Start, or run Calc. Qty. Available to Start after switching MES on for existing orders.

  • Is another Workspace already running it? If Exclude Ops. on Other Devices is on, it's hidden.

  • Has the operation been completed in MES? It no longer appears.

Licensing and Workspace messages

 
Message What it means

No. of allowed Application Terminals exceeds the license count for Clever MES

You've reached your licensed number of Terminals. Licensing and Terminals

Your Clever MES license has expired.

Your licence has expired.

Cannot create a device for Work Center X because a Machine Center with the same No. already exists.

A Work Centre and a Machine Centre share a number. Renumber one.

Workspace X cannot be deleted because Production Order Y is running on it.

Stop and exit the operation before deleting the Workspace.

Production Order X cannot be deleted because it is running on device Y.

Stop and exit the operation first.

Machine X is currently in use, the process type cannot be changed.

Change the centre's Process Type when nobody is working on it.

 

Other setup errors

 
Message Cause

You cannot use the X MES Document Type because it is already used in Y.

The same item is chosen in two Data Selection fields.

Output cannot be posted when no centre is selected.

The Workspace has no centre stored.

There is a missing Operator Dimension mapping for Operator Entry No. X

Post Operator Dimensions is on but the operator's dimensions aren't set up.

By-Product Output Bin X must not be of type Receive, Ship or Pick.

Choose a different bin on the location.